3009
Replacement of the flowmeter unit by a Flow Gauge
with Gauge Saver and a rugged all metal
construction ensures less frequent & reduced
maintenance / servicing. Tamper-proof Safety Blow
off situated inside the regulator prevents
unauthorized adjustment of blow off pressure.
Larger Control Knob provides more convenient
operation. |
 |
|
|
| |
3008
The Regulator has a factory preset fixed static outlet
pressure of approx. 4.2 Kg/Sq.cm (60 lbs/sqin) and is
fitted with safety valve. Once the flowrate has been
set, the regulator will automatically maintain a
constant flow rate irrespective of changing volume of
cylinder contents. If the oxygen line distal to the
regulator should be blocked, the regulator
automatically prevents the build up of an excessive
pressure in the apparatus and tubing between the
outlet of the regulator and the obstruction. A
pressure gauge indicates the cylinder contents. |
 |
|
|
| |
3041 - Metal
The Back Pressure Compensated (BPC) flowmeter
incorporates a rotary pin valve control to permit
adjustment of the flow rate to any desired level
between 0 - 15 ltrs/min. Jacketed type shatterproof
tubes are fitted on the units The outlet at the bottom
of the unit is fitted with a removable nipple. After
removing the outlet nipple, a humidifier can be
screwed into the outlet of the flowmeter unit. Flow
accuracy is unaffected by back pressure due to down
stream restrictions caused by humidifiers, nebulizers
etc.
|
 |
| 3010 - Plastic |
 |
| Note : The BPC Flowmeter with control used in the
regulator should not be used with F/A valve. |
|
|
|
| |
3006
Set comprises of F/A Valve with Gauge (3005),
Flowmeter (3007) & Gauge Saver (3115)
The unit reduces the cylinder pressure by merely
providing a variable restriction to the flow of Oxygen
from the cylinder outlet. As volume of Oxygen in the
cylinder reduces, the flowmeter has to be constantly
adjusted to maintain the required flowrate. The
flowmeter unit without control is fitted with jacketed
type shatter proof tubes calibrated from
0-15ltrs/min.
|
 |
Note : The flowmeter without control used in the F/A
Valve should not be used with an Oxygen Regulator. |
|
|
|
| |
3007 |
 |
Note : The flowmeter without control used in the F/A
Valve should not be used with an Oxygen Regulator. |
|
|
|
| |
| 3113 - 50 mm Dia, 0-250 Kgs/cm2 |
 |
|
|
| |
Consists of an unbreakable jar with screw on cap
fitted on top inlet and side outlet tubes. The inlet
tube ends in a specially designed diffuser from which
oxygen is bubbled through water before reaching the
outlet.
3013 - Humidifier with “S” Hook - for hanging on the
cylinder trolley or flowmeter unit. |
 |
3050 - Humidifier - screw on type - Metal Inlet |
 |
3012 - Humidifier - screw on type - Plastic Inlet
Provided with 1/2” BSF threads that can be screwed
on directly to the outlet of the flowmeter. |
 |
3051 - Humidifier - for generator - Metal Inlet |
 |
3040 - Humidifier - for generator - Plastic Inlet
For use with an Oxygen Generator / Amar Oxygen
Regulator. Has a 9/16 UNF female knurled nut &
nipple at the inlet. |
 |
|
|
| |
3014 - Adult
3015 - Child
3016 - Neonatal
Not just another oxygen nasal cannula - the ‘U’
shaped moulding with limbs which is inserted into
the nostrils will not hurt the patient when inserted.
Extremely light in weight, the nasal tips ensure a
comfortable fit for efficient oxygen therapy.
Supplied with 2 meters tubing. |
 |
|
|
| |
3017 - Adult
3018 - Child
Light weight design, soft feathered edges for
increased patient comfort, nose clip for nose bridge
adjustment & for better fit, pull through adjustable
elastic head band & swivel tubing connector for
changing angle of operation without disturbing the
mask. |
 |
|
|
| |
3020 - Adult
3021 - Child
One piece adjustable venturi valve with a choice of
seven oxygen percentage settings (24, 26, 28, 31,
35, 40 & 45%) allowing the concentration of oxygen
delivered to the patient to be set and changed as
clinically as is required. Eliminates use of several
selector venturi valves thus significantly reducing the
time required to change oxygen concentrations. |
 |
|
|
| |
3037 - Adult
3038 - Child
High concentration Oxygen Mask is used to deliver
100% Oxygen to patient. There is a two litre
reservoir bag with 3 one-way valves to deliver 100%
Oxygen. Two expiratory valves are easily detachable
as per the need of the patients. |
 |
|
|
| |
3031 - Adult
3032 - Child
Set comprises of plain Oxygen Mask, Nebuliser Jar &
tubing. The nebuliser jar is specially designed for the
delivery of drugs for tracheobronchial deposition. At
gas flow of 8 L/min, 70% of output will be particles of
less then 5 microns. |
 |
|
|
| |
3039
Mouthpiece is particularly useful for patients who can
coordinate their breathing for drug delivery, thereby
increasing the amount of aerosol reaching the lungs. |
 |
|
|
| |
3026
A ventilating system for rigid wall
bronchoscopy and laryngeal microsurgery.
Comprises : 2mtrs. High Pressure Tubing,
Thumb Valve Control and three Luer Lock Needles. |
 |
|
|
| |
3027
Specially introduced for use with the Jet
Ventilator and other applications, it has an extra
gauge to indicate the outlet pressure of the regulator
and incorporates a safety valve. The outlet pressure
can be adjusted with the help of the key to desired
value depending upon use for Paediatric or Adult
patients. |
 |
|
|
| |
3023
Combination Key & Spanner - For fitting
Regulators & F/A Valves onto Cylinders and for
opening Bull Nose type Cylinders. Cannot be used to
open Pin Index type Cylinders. |
 |
3028
Multipurpose - For fitting flowmeters onto F/A
Valves or Regulators, Hex Nuts onto Bull Nose type& Flush type Cylinders & for opening and closing both
Bull Nose type as well as Pin Index type Cylinders. |
 |
3024
Key for Pin Index Cylinders - For opening Pin
Index type Cylinders & fitting Hex Nuts to the valves. |
 |
|
|
| |
3011
For using two BPC flowmeters from one
oxygen regulator. |
 |
|