| 3601 - Oxygen |
0.1 to 10.0 ltr/min
100 to 10000 cc/min |
| 3602 - Nitrous Oxide |
0.2 to 12.0 ltr/min
200 to 12000 cc/min |
| 3612 - Air |
0.1 to 12.0 ltr/min
100 to 12000 cc/min |
| 3613 - Oxygen |
0 to 1.0 ltr/min
0 to 1000 cc/min |
Dual tapered calibrated tube calibrated at 20OC &
1013mbar abs.
Bobbin Float : Aluminium alloy anodised red, with
silver dot for easy observation of rotation.
Operation of the tubes can be easily confirmed by
checking the location of flowmeter bobbin & by
seeing the rotation of the bobbin. |
|
|
|
|
| |
3652 - Oxygen
Colour coded plastic cover, other components from stainless steel to avoid
rusting, pin indexed for use on anaesthesia trolley. |
 |
| |
|
| 3653 - Nitrous Oxide |
 |
|
|
| |
3650 - Oxygen
3651 - Nitrous Oxide
One piece, brass chromed, robust & pin indexed for use on anaesthesia trolley. |
 |
|
|
| |
3654 - Oxygen for use with F. A. Valve
3655 - Nitrous Oxide
3656 - Oxygen for use with Rao’s Regulator
For use other than anaesthesia trolley. Pin indexed, brass chromed, specially
developed for flush type portable cylinders for use with portable anaesthesia
apparatus. Ideal for domiciliary use, ambulances, mines, airports, railways and
medical disaster situations. |
 |
|
|
| |
3604
Normally positioned at the top of the apparatus table. It has a
built in emergency oxygen push button and change over facility
from open to closed circuit and vice versa. |
 |
|
|
| |
3606
Incorporates a non-return valves assembly along with a button
for flushing the circuit with oxygen in emergencies. |
 |
|
|
| |
3603
Blows off when pressure exeeds 200cms of water column thus
minimising the risk of back flow of gases. |
 |
|
|
| |
3607
A battery operated pnuematically controlled device which
activates an audio alarm for about fifteen seconds when oxygen
pressure in the system falls to approximately 4.2kg/cm2 |
 |
|
|
| |
4002
Drawover type, designed to limit the maximum concentration of
Halothane vapour to 3% by volume irrespective of the total gas
flow through the unit. Adjustment is made by means of a ratchet
type control valve. The glass jar is screwed on to the body and
can be quickly detached for easy filling. The vaporizer is also
suitable for use with Trichloroethylene in low concentrations. |
 |
|
|
| |
3625 - Oxygen
3626 - Nitrous Oxide
For use with anaesthesia apparatus only. Outlets have nonreturn
valves to avoid back flow of gases. Safety valve is
incorporated in the unit. Hence no necessity of safety valve in
the tubing between the regulator and the rotameter unit. |
 |
|
|
| |
3629
To activate Nitrous Oxide Regulators only when Oxygen
Regulators are pressurised, thereby minimising the risk of
administering Nitrous Oxide in the absence of Oxygen. Safety
valve incorporated in the unit. Hence no necessity of safety valve
in the tubing between the regulator & the rotameter unit. |
 |
|
|
| |
3675 - Oxygen
3676 - Nitrous Oxide
For connecting bulk cylinder to the anaesthesia apparatus. The
unit comprises of a Regulator, 2 mtrs. High Pressure Tubing with
ferrules and a Pin Index Adaptor to fit on the yoke of the
apparatus in place of the service cylinder. |
 |
| |
|
| |
 |
|
|
| |
9023 - 22F x 22M & 22F at Bag end - Plastic
9025 - 23M x 23F & 22 F at Bag end - Plastic
The above will not bend or dent when accidentally dropped.
|
 |
| |
|
| 9027 - 23M x 23F & 23 M at Bag end with ON/OFF Lever - Brass
chromed. |
 |
|
|
| |
9200 - 22M/15F at patient end & 22F at distal end
9201 - 23M/15F at patient end & 23F at distal end
15mm E/T straight connectors can be fitted at the patient end,
thus avoid using catheter mount & reducing dead space. Will not
bend or dent when accidentally dropped.
|
 |
9202 - 23M/23F Brass Chromed
A variable tension spring is fitted in the above three expiratory
valves to control the degree of rebreathing. |
 |
|
|
| |
9028
The patient end accepts anaesthesia mask & 15mm tracheal
connector. |
 |
|
|
| |
9050
Patient end accepts anaesthesia mask & 15mm tracheal
connector. Low weight - 50gms - leads to minimization of the
pressure strain for patient. Sturdy to withstand rough usage, will
not bend or dent when accidentally dropped, needs no servicing
with absence of circlips & rubber washers. |
 |
|
| |
| |